Video Guides
Fabric wrinkle solution
Thread breaking solution 1
Thread jumper solution
Fabric wrinkle solution
Thread breaking solution 1
Scissors position adjustment
Thread jumper solution
Restore Factory Setting
Enter advanced parameters
Set the function of lifting the presser foot after half-back
Correct motor angle
Fabric wrinkle solution
Thread breaking solution 1
Scissors position adjustment
Thread jumper solution
View the version number
Port definition
Reverse needle lifting function
Change thread trimming speed
Replace the encoder
Replace the motor
Turn off no oil alarm
Turn off automatic presser foot lift
Restore Factory Setting
Judge whether the motor is good or not
Set presser foot lifting time
Set the stop needle position
Set the action mode of the small thread clamp
Adjust handwheel positioning
Detection method of no function
Correct motor angle
Fabric wrinkle solution
Thread breaking solution 1
Thread jumper solution
Adjust sewing speed
Stop needle position
Slow starting sewing switch
Slow starting sewing speed
Number of stitches for slow sewing 2
Upper stop needle position adjustment
Maximum speed change
Restore Factory Setting
Needle bar height, hook adjustment
Control box and motor disassembly
Adjustment of scissors position
Fabric wrinkle solution
Thread breaking solution
Thread jumper solution
Motor angle correction
Automatic presser foot lifting function setting
Restore Factory Setting
Enter advanced parameters
Panel icon introduction
Set broadcast language
Set solenoid overcurrent protection function
Set the reverse needle lifting function
Set sewing speed
Set cutting speed
Set lock screen time
Set forward and reverse
Set the time for automatic presser foot lifting
Change the bartacking speed
Set fixed stitch sewing speed
Oil level alarm detection
Control box and motor installation method
Control box and motor disassembly method
Fabric wrinkle solution
Thread breakage solution
Needle breakage solution
Scissors adjustment
Thread jumper solution
Fabric wrinkle solution
Thread breaking solution 1
Thread jumper solution
Motor angle correction
Automatic presser foot lifting function setting
Change the sewing speed
Restore Factory Setting
Enter advanced parameters
Panel icon introduction
Set broadcast language
Set solenoid overcurrent protection function
Set the reverse needle lifting function
Set cutting speed
Set the motor forward and reverse
Set lock screen time
Set the time for automatic presser foot lifting
Set fixed stitch sewing speed
Set the speed of bartacking
Oil level alarm detection
Fabric wrinkle solution
Thread breaking solution 1
Thread jumper solution
Differential ratio adjustment
Feeding dog height adjustment
Height adjustment of cloth cutting knife
Cutter adjustment
Width adjustment of cloth cutting knife
Looper adjustment 1
Presser foot adjustment
Stitch length adjustment
Differential ratio adjustment
Feeding dog height adjustment
Height adjustment of cloth cutting knife
Cutter adjustment
Width adjustment of cloth cutting knife
Looper adjustment 1
Presser foot adjustment
Stitch length adjustment
Presser foot lift mode in sewing
Change speed
Needle stop position selection after thread trimming
Enter advanced parameters
Set the presser foot lifter
Set the brightness of the headlight
Set intermittent suction stop time
Set intermittent suction inhale time
Set the presser foot mode after thread trimming
Set startup mode
Set sewing speed
Set the front receiver switch
Set manual trimming suction
Set the stop position
Set automaticsemi-automatic mode
Automatic sensor switch
Automatic trimming settings
Auto cloth spread setting
Automatic presser foot lifter setting
Automatic suction setting
Differential ratio adjustment
Feeding dog height adjustment
Height adjustment of cloth cutting knife
Cutter adjustment
Width adjustment of cloth cutting knife
Looper adjustment 1
Presser foot adjustment
Stitch length adjustment
Change the sewing speed
Change soft start speed
Change the number of soft start pins
Change the minimum speed
Change the maximum speed
Automatically find the needle stop position when starting up
Set soft start function
Set the stop position
Adjust the upper position of the needle bar
Adjust the lower position of the needle bar
Sewing speed
Stop needle positioning selection
Sewing speed
Start mode
Automatic&semi-automatic mode
Automatic suction
Automatic presser foot lift
Lift the presser foot in sewing
Lift the presser foot after trimming
Half back press foot pedal
Manual suction
Headlight brightness
Differential ratio adjustment
Feeding dog height adjustment
Height adjustment of cloth cutting knife
Cutter adjustment
Width adjustment of cloth cutting knife
Looper adjustment 1
Looper adjustment 2
Presser foot adjustment
Stitch length adjustment
Scissors stroke adjustment
Scissors return adjustment
Scissors position adjustment(front&back)
Position adjustment of moving knife and fixed knife
Scissors stroke adjustment
Scissors return adjustment
Scissors position adjustment(front&back)
Position adjustment of moving knife and fixed knife
Adjust the gap between the needle guard and the needle
Looper stroke adjustment
Adjust the gap between the looper and the needle
Needle bar height adjustment
Feeding dog height adjustment
Feeding speed adjustment of feeding dog
Scissors stroke adjustment
Scissors return adjustment
Scissors position adjustment(front&back)
Position adjustment of moving knife and fixed knife
Adjust the gap between the needle guard and the needle
Looper stroke adjustment
Adjust the gap between the looper and the needle
Needle bar height adjustment
Feeding dog height adjustment
Feeding speed adjustment of feeding dog
Adjust sewing speed
Needle stop positioning selection
Slow starting speed
Number of stitches at low speed
Slow start
Headlight brightness adjustment
Motor direction rotation setting
Needle raising switch after thread trimming
Working hours for full force when lifting the presser foot
Lower thread trimming time
Upper positioning adjustment
Lower positioning adjustment
Machine head protection switch
Tangent protection switch
Suction selection
Solenoid overcurrent protection
Scissors stroke adjustment
Scissors return adjustment
Scissors position adjustment(front&back)
Position adjustment of moving knife and fixed knife
Adjust the gap between the needle guard and the needle
Looper stroke adjustment
Adjust the gap between the looper and the needle
Needle bar height adjustment
Feeding dog height adjustment
Feeding speed adjustment of feeding dog
Edit pattern
Edit pattern name
Test XY motor
View modified parameters
Presser foot status after sewing
The thread clamp opens or closes after sewing
Change motor current
Change machine model
Change the starting point
change language
Change the stitch length
Pattern export
Pattern import
Restore Factory Setting
Fast forward operation
Thread clamp switch when sewing starts
Delete pattern
Set blowing function and time
Set the number of bobbin thread stitches
Set fuel supply time
Set up reinforcement sewing
Set cutting speed
Set soft start speed
Set medium presser motor port
Set spindle motor angle
Action mode of small thread clamp
Needle bar stop position
Removal and installation of condenser
Adjust the height of the needle bar and the position of the hook
X motor installation and test
Y motor installation and test
Step angle configuration of template machine
Installation of medium presser foot motor for template machine
Install and test spindle motor for template machine
X motor installation
Y motor installation
Medium presser foot installation
Spindle motor installation
Disassembly and installation of condenser
Adjust the height of the needle bar and the position of the hook
Step angle configuration of template machine
Parameter backup
Startup mode setting
Pattern export
Sort
Machine model selection
Segment switching
Adjust sewing range
Pattern import
Restore factory parameters
Mirror
Jump
Frame pressing action after sewing
language selection
Air pressure detection switch
Simulated trial sewing
End-to-end swap
Oil filling time
Needle stop position
Whether thread breaking detection is on
Start sewing and end reinforcement mode setting
State of medium presser foot and auxiliary presser foot during trial sewing
Speedgear of returning to origin at the end of sewing
Whether to allow trimming
Laser cutter switch
Idle feed speed gear
Start speed and end speed
Sewing speed
Whether to return to the origin after sewing
Modify stitch length
Blow function
Pattern deletion
Add function code
Create new pattern
Modify the starting point
End-to-end expansion
RF card reading
X motor Disassembly and installation
Y motor Disassembly and installation
Servo parameter export
Test laser action
Check the running direction of XY motor
Scissors adjustment
Installation and test of trimming motor
Disassembly and installation of condenser
Output function detection
Input function detection
Disassembly and installation of medium presser foot motor
Medium presser foot motor detection
Height adjustment of medium presser foot
Import of servo parameters
Detect the volume of hook oil supply
Software upgrade method
Disassembly and installation of spindle motor
Configuration parameter upgrade method
Adjust the height of the auxiliary presser foot
Adjust the height of the needle bar and the position of the hook
Modify X and Y direction offset parameters
Configuration parameters, UK, servo restore all
change language
Change pattern, XY zoom speed
Simulated action
Registration of P pattern
Delete P pattern
C pattern registration
Delete C pattern
XY origin adjustment
Turn on the maximum sewing speed
Soft start
Emergency stop function
Prohibit thread cutting
Prohibit lifting the presser foot
Set the needle bar position
Type of pedal
Cutting speed
XY movement range change
Cutting angle
Trimming action method
Spindle motor type
Machine model selection
Import pattern from U disk
Open hidden parameters
Restore Factory Setting
View version number
Upgrade main control
Upgrade panel
Detect pedal status
Detect spindle angle
Detect spindle motor
Detect presser foot motor
Main clamp solenoid
Hook adjustment
LOGO light does not work
The headlight does not work
Adjustment of the thread wiper
Loose thread solenoid detection
Presser foot height adjustment
Spindle motor installation
Test pattern
Open hidden patterns
Change pattern magnification
Change the pattern speed
Change thread trimming speed
Change the maximum speed
Piece counting function
Set C pattern
Set P pattern
Switch bartacking and buttoning program
Hook adjustment
Adjust the thread wiper
Adjust the height of the presser foot
Spindle motor installation
Hook adjustment
The headlight does not work
Adjustment of the thread wiper
Loose thread solenoid detection
Presser foot height adjustment
Spindle motor installation
Register pattern
Change the hemming width
Change single and double stitch
Change the length of the pattern
Change the number of lower sewing
Change thread tension
Change the width of the right cutter groove
Change the width of the left cutter groove
Pattern naming
Set cutter function
Set up trial sewing
Set cycle stitch
Disassembly and installation of cloth cutting knife motor
Disassembly and installation of needle bar motor
Upper trimming position adjustment
Disassembly and installation of upper thread trimming motor
Disassembly and installation of feeding motor
Disassembly and installation of presser foot motor
Bottom trimming position adjustment
Disassembly and installation of lower thread trimming motor
Needle bar and hook position adjustment
Disassembly and installation of spindle motor
Output function detection
Input function detection
X motor detection
Y sensor detection
Y motor detection
Z motor detection
Stretch cloth detection
Bottom thread solenoid
Cutting knife of bottom thread detection
Upper scissors
Upper thread solenoid detection
Air hammer detection
Upper needle stop sensor
Presser foot detection
Spindle motor sensor
Stretch cloth function switch
Change size
Change size
Change the pattern pitch
Change the length of the pattern bartacking
Change the number of round head stitches
Change cutter interval
Change speed
Change speed
Switching of cutter action
Set cycle pattern
X position adjustment
Y position adjustment
Z position adjustment
Swing width adjustment
Clearance adjustment between needle and looper
Edit curve pattern
Edit round zigzag pattern
Edit circular pattern
Edit straight line
Edit straight zigzag patterns
Test XY motors and sensors
View version
View modified parameters
Change motor current
Change the starting point of the pattern
Change zone speed
change language
Pattern export
Pattern import
Change the stitch length of the pattern
Restore Factory Setting
Detection mode
Simulated sewing
Offset line segment
Set the second origin
Set the speed of returning to the sewing point
Set soft start
Set cycle pattern
Jump stitch operation
Select pattern
Select machine model
Adjustment of the gap between the needle bar and the shuttle
Points for adjusting the stroke of the wiper
Parallel movement
Edit jagged circles
Edit straight lines and curves
Change the start point of the second line
Change zone speed
Edit Chrysanthemum Eyes
Export pattern
Add second origin
Add flip presser foot code
Import pattern 1
Pattern machine initialization
XY medium presser foot detection mode
Points for adjusting the stroke of the wiper
Introduction of motor name and purpose
Positioning and installation of thread trimming cam
Cutter adjustment
Tangent solenoid detection mode
Output detection of wiper solenoid
Adjustment of the gap between the needle bar and the shuttle
Removal and installation of medium presser foot motor
Adjustment of the synchronization time of medium presser foot
Disassembly and installation of spindle motor
Install the needle plate
Needle bar switching failure adjustment
Hook position adjustment
The cloth can't be pressed(adjustment method)
Synchronous adjustment
dog height adjustment
Needle bar height adjustment
Poor thread trimming adjustment
Needle deviation adjustment
dog position adjustment(front&back)
Install the needle plate
Hook position adjustment
The cloth can't be pressed(adjustment method)
Synchronous adjustment
dog height adjustment
Poor thread trimming adjustment
Needle deviation adjustment
dog position adjustment(front&back)
Install the needle plate
Hook position adjustment
The cloth can't be pressed(adjustment method)
Synchronous adjustment
dog height adjustment
Needle deviation adjustment
dog position adjustment(front&back)
Install the needle plate
Hook position adjustment
The cloth can't be pressed(adjustment method)
Synchronous adjustment
dog height adjustment
Needle bar height adjustment
Needle deviation adjustment
dog position adjustment(front&back)
Edit pattern
View version
View modified parameters
Zero correction
Delete pattern
Set the swing width method
Set wiper time
Set back stitch compensation
Set pattern sewing parameters
Set front and back reinforce sewing
Set trimming speed
Select pattern
Select language
Feed dog adjustment
Synchronous position adjustment
Change pattern
Change speed
Change the swing width
Chinese and English switching
Swing width restriction
Needle numbers of soft start
Soft start speed
Pattern import
Version number check
Upgrade procedure
Change the stop position
Adjust contrast
Maximum speed setting
Pattern removal
Safety switch
Restore Factory Setting
Change the start point of the zigzag stitch
Swing needle motor detection and origin adjustment
Width adjustment of swing needle
No movement detection when wiping
No movement detection of reverse stitching
Disassembly and installation of control box
reset to the factory setting
No movement detection of thread trimming
Software version query
Panel inspection method
Input and output function detection
No movement detection of loose thread
Feed dog adjustment
No movement detection of thread take-up
Adjust the center position of the needle bar
Synchronous position adjustment
Hook oil supply adjustment
Needle bar height, hook adjustment
Spindle motor detection
Spindle motor zero calibration
No movement detection of automatic lift presser foot
Change the sewing speed
Restore Factory Setting
Set overturn protection mode
Set the direction of motor rotation
Set needle stop position and soft start
Set maximum speed
Needle bar synchronization adjustment
Scissors position adjustment
Thread trimming cam adjustment
Feeding dog position adjustment
Hook position adjustment
Large presser foot height adjustment
Height adjustment of large and small presser foot
Alternative height raise of large and small presser foot
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Manual reverse sewing action time exceeds 15 seconds
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
Hardware overcurrent
Software overcurrent
Overvoltage during shutdown
Undervoltage during shutdown
Overvoltage during operation
Stop needle signal malfunction
Motor HALL signal fault
Motor stalling fault
Overspeed fault
Undervoltage during operation
HALLA signal loss
Motor overload
EEPROM error
Current detection circuit fault
Pedal zero position detection exceeds the limit
OZ circuit malfunction
Motor reversal
Motor angle test malfunction
The foot pedal is not in the center position
The machine enters an emergency stop state
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Auxiliary equipment voltage (24V) too high
Auxiliary equipment voltage (24V) too low
Air valve short circuit or fan blockage
X motor out of tolerance fault
Encoder malfunction or disconnection
Abnormal operation of the motor
Beyond the sewing area
Abnormal position on the needle bar
Wire breakage detection error
The emergency stop switch is not in the normal position
Step version error
Abnormal position of the grabbing line
Incorrect connection between operation panel and sewing machine
X origin detection anomaly
Y origin detection anomaly
Abnormal foot origin detection
Abnormal detection of the origin point of the grab line
Abnormal origin detection of medium voltage foot
Stepper driver communication exception
Stepper motor overcurrent
Stepper drive power supply abnormality
IPM overcurrent 1
IPM overcurrent 2
Motor stalling 1
Motor stalling 2
Motor overload
Y motor overspeed fault
Y motor out of tolerance fault
Medium voltage foot overspeed
Medium voltage foot out of tolerance
External pressure foot exceeds the tolerance
Y motor high current
Quick move curve calculation error
Unrecognized template
The parameters of the main control step curve do not match
Wire cutting motor overcurrent
Abnormal medium voltage foot motor
Abnormal wire cutting motor
Abnormal card reading module
90V overload
The control box does not match the type of operating head
Pattern NO. Abnormal
Abnormal alarm for supplementing lubricating oil
Abnormal position on the needle bar
Abnormal flipping of the machine head
Abnormal 24V power supply
Abnormal foot pressure position
Abnormal position of the grabbing line
Abnormal position of tangent cutter
Beyond the sewing area
Beyond the sewing area
pause
Operation head pattern parameter is empty
Abnormal range of memory parameters for operation head
Abnormal range of parameters read from the lower computer panel
Abnormal operation head pattern parameters
Abnormal range of operating head pattern parameters
Abnormal format of operation header pattern data
The external pattern storage space of the operation head is full
Abnormal format of external pattern storage area for operation head
The USB pattern imported by the operation head already exists
Operation head imported USB pattern not found
Operation head deleting external pattern error
Error reading external pattern by operating head
Abnormal reading and writing of USB storage device by the operating head
Abnormal model parameters
Main control firmware program verification error
Upgrade of main control firmware program failed
Panel firmware program not found
Panel firmware program verification error
Panel firmware program upgrade failed
The foot pedal is not in the center position
Air valve (fan) malfunction
Abnormal operation of the motor
The emergency stop switch is not in the normal position
Machine aging stops
Step by step closed-loop DSP1 (X25/X27) communication error
Step by step closed-loop DSP1 first channel (X27) overcurrent
Step by step closed-loop DSP1 first path (X27) out of tolerance
Step by step closed-loop DSP1 first path (X27) overspeed
Step by step closed-loop DSP1 second channel (X25) overcurrent
Step by step closed-loop DSP1 second channel (X25) out of tolerance
Step by step closed-loop DSP1 second channel (X25) overspeed
Step by step closed-loop DSP2 (X21/X23) communication error
Step by step closed-loop DSP2 first channel (X23) overcurrent
Step by step closed-loop DSP2 first path (X23) out of tolerance
Step by step closed-loop DSP2 first path (X23) overspeed
Step by step closed-loop DSP2 second channel (X21) overcurrent
Step by step closed-loop DSP2 second channel (X21) out of tolerance
Step by step closed-loop DSP2 second channel (X21) overspeed
Machine locked
Encoder not connected
Main spindle overcurrent
Abnormal parking current
Instantaneous overcurrent of motherboard IPM
The motherboard IPM has experienced multiple overcurrent events
Main spindle overspeed
Abnormal high voltage
Abnormal low voltage
Poor spindle drive
The spindle position is incorrect
Stepper drive abnormality
Abnormal 24V power supply
X origin search exception
Y origin search exception
Abnormal origin search of wire cutting motor
Abnormal search for the origin of the presser foot
Capture the origin of the line and search for anomalies
Main circuit board - operation panel communication abnormality
Main circuit board - stepper circuit board communication abnormality
Abnormal parameters of the lower computer head board
Operation head circuit board EEPROM read/write error
Undefined error
The foot pedal is not in the center position
The machine enters an emergency stop state
Head flipping error
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Abnormal overvoltage of auxiliary equipment voltage (24V)
Abnormal undervoltage of auxiliary equipment voltage (24V)
Air valve (fan) malfunction
Abnormal foot pressure position
Encoder malfunction or disconnection
Abnormal operation of the motor
Exceeding the sewing area during movement
Abnormal position on the needle bar
Wire breakage detection error
Abnormal position of wire cutter
The emergency stop switch is not in the normal position
Stepper software version error
Machine enters emergency stop state (Free)
Machine enters emergency stop state (Ready)
Abnormal position of the grabbing line
Incorrect connection between the operating head and the sewing machine
X origin detection anomaly
Y origin detection anomaly
Abnormal foot origin detection
Abnormal detection of the origin point of the grab line
Abnormal origin detection of medium voltage foot
Stepper driver communication exception
Stepper motor overcurrent
Stepper drive power supply abnormality
abnormal current
IPM frequent overcurrent 1
IPM frequent overcurrent 2
Motor stalling 1
Motor stalling 2
Motor overspeed
Parking overcurrent
Motor overload
Abnormal bus voltage
Abnormal origin of wire cutting motor
Head board EEROM read/write error
MD1 step overcurrent
MD2 step overcurrent
Step by step closed-loop DSP1 (X25/X27) communication error
Step by step closed-loop DSP1 first channel (X27) overcurrent
Step by step closed-loop DSP1 first path (X27) out of tolerance
Step by step closed-loop DSP1 second channel (X25) overcurrent
Step by step closed-loop DSP2 first path (X23) out of tolerance
Step by step closed-loop DSP1 second channel (X25) overcurrent
Step by step closed-loop DSP2 second channel (X21) out of tolerance
90V power overcurrent for stepper board
The pedal is not in the center position
The machine enters an emergency stop state
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Auxiliary equipment voltage (24V) too high
Auxiliary equipment voltage (24V) too low
Air valve short circuit or fan blockage
Encoder malfunction or disconnection
Abnormal operation of the motor
Exceeding the sewing range during movement
Abnormal position on the needle bar
Wire breakage detection error
Abnormal position of wire cutter
The emergency stop switch is not in the normal position
Step version error
Abnormal position of the grabbing line
Incorrect connection between operation panel and sewing machine
X origin detection anomaly
Y origin detection anomaly
Abnormal detection of the origin point of the grab line
Abnormal origin detection of medium voltage foot
Stepper driver communication exception
Stepper motor overcurrent
abnormal current
IPM overcurrent 1
IPM overcurrent 2
Motor stalling 1
Motor stalling 2
Motor overspeed
Motor overload
Abnormal bus voltage
X motor overspeed fault
Y motor out of tolerance fault
Insufficient bottom line
Overcurrent of medium voltage foot motor
Y motor overcurrent
Insufficient air pressure
X motor stalling
Y motor stalling
X motor overcurrent
Wire grabbing motor overcurrent
Insufficient oil in the oil box, please add lubrication
Abnormal card reading module
90V overload
Undefined error
The foot pedal is not in the normal position in the free state
Machine enters emergency stop
Main voltage (300V) too low
Main voltage (300V) too high
Main spindle overspeed
IPM overvoltage or overcurrent
Auxiliary equipment 24V overvoltage
Auxiliary equipment 24V undervoltage
Spindle motor stalling
IPM overcurrent
IPM overcurrent
Encoder malfunction or disconnection
Abnormal operation of spindle motor
Beyond the sewing area
Abnormal position on the needle bar
Wire breakage detection error
Abnormal position of the cutting blade
Head flipping error
X origin detection anomaly
Y origin detection anomaly
Abnormal foot origin detection
Abnormal origin detection of section line
Abnormal detection of cutting line origin
Stepper driver communication exception
Stepper motor overcurrent
Sewing beyond the sewing range
Abnormal position of the cutting line
Abnormal cutting line position
The cutter returns abnormally
Zero position pulse abnormality
Step version error
Pattern transmission error
Parameter transmission error
Head EEPROM reading error
CRC check error
Password verification error
The longest position of the pattern does not match the actual walking position
The number of steps for the X-direction main control and step verification is inconsistent
The Y-direction main control and step verification steps are inconsistent
Needle motor overcurrent
Cutting blade motor overcurrent
Needle motor overspeed
Cutting blade motor overspeed
Needle motor out of tolerance
The cutter motor is out of tolerance
Needle motor command coverage
Knife motor command coverage
MD1EEP read error
MD1 communication error
Overcurrent of fabric feeding motor
Pressure foot motor overcurrent
Delivery motor overspeed
Foot press motor overspeed
The fabric delivery motor is out of tolerance
The presser foot motor is out of tolerance
Cover the instruction of the fabric delivery motor
Foot press motor command coverage
MD2 EEP read error
MD2 communication error
Spindle zero position timeout
Abnormal cooling fan
IPM frequently experiences overcurrent
24V overcurrent
24V undervoltage
Machine head board parameter reading error
Abnormal motor operation (spindle motor stalling)
Press the emergency stop switch while in standby mode
I pressed the emergency stop switch while sewing
Poor contact of emergency stop switch
The starting pedal is not in the normal position
The foot pedal is not in the normal position
Machine head flipped over incorrectly
Needle stop position error
Poor connection of synchronization signal detector (spindle not connected)
Abnormal origin of X-axis
Y-axis origin abnormality
Z-axis origin abnormality
IPM overcurrent 1
IPM overcurrent 2
Step version exception
Abnormal bottom line cutting
The air hammer has dropped, but its position is abnormal
The air hammer does not descend, and the position of the air hammer is abnormal
300V overvoltage
300V undervoltage
Step by step overcurrent
Cooling fan not working
The air hammer cannot descend to the bottom
Stepper board communication abnormality
Abnormal operation of X motor
Abnormal operation of Y motor
The fabric board has exceeded the boundary
Abnormal operation of Z motor
Abnormal closed-loop of spindle motor
Abnormal spindle zero position signal
Abnormal spindle encoder
Abnormal spindle stop
Sewing stopped abnormally
SPI communication is busy
Internal and external needle signal error
Wrong number of stitches for pattern sewing
Abnormal spindle speed
abnormal atmospheric pressure
X motor overcurrent
Y motor overcurrent
X motor out of tolerance
Y motor out of tolerance
X motor overspeed
Y motor overspeed
DSP1 communication abnormality
Z motor overcurrent
Z motor out of tolerance
Z motor overspeed
DSP2 communication abnormality
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Abnormal positioning signal
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The foot protection switch is not in the correct position
The head protection switch is not in the correct position
Head overturned
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Auxiliary equipment voltage (24V) too high
Auxiliary equipment voltage (24V) too low
Encoder malfunction or disconnection
Abnormal operation of the motor
Exceeding the sewing range during movement
Abnormal position on the needle bar
Stepper software version error
X origin detection anomaly
Y origin detection anomaly
Stepper driver communication exception
Stepper motor overcurrent
abnormal current
IPM frequent overcurrent 1
IPM frequent overcurrent 2
Motor stalling 1
Motor stalling 2
The foot pedal is not in the center position
The machine enters an emergency stop state
Head flipping error
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Abnormal overvoltage of auxiliary equipment voltage (24V)
Abnormal undervoltage of auxiliary equipment voltage (24V)
Air valve (fan) malfunction
Abnormal foot pressure position
Encoder malfunction or disconnection
Abnormal operation of the motor
Exceeding the sewing area during movement
Abnormal position on the needle bar
Wire breakage detection error
Abnormal position of wire cutter
The emergency stop switch is not in the normal position
Stepper software version error
Machine enters emergency stop state (Free)
Machine enters emergency stop state (Ready)
Abnormal position of the grabbing line
Incorrect connection between the operating head and the sewing machine
X origin detection anomaly
Y origin detection anomaly
Abnormal foot origin detection
Abnormal detection of the origin point of the grab line
Abnormal origin detection of medium voltage foot
Stepper driver communication exception
Stepper motor overcurrent
Stepper drive power supply abnormality
abnormal current
IPM frequent overcurrent 1
IPM frequent overcurrent 2
Motor stalling 1
Motor stalling 2
Motor overspeed
Parking overcurrent
Motor overload
Abnormal bus voltage
Abnormal origin of wire cutting motor
Head board EEROM read/write error
MD1 step overcurrent
MD2 step overcurrent
Step by step closed-loop DSP1 (X25/X27) communication error
Step by step closed-loop DSP1 first channel (X27) overcurrent
Step by step closed-loop DSP1 first path (X27) out of tolerance
Step by step closed-loop DSP1 second channel (X25) overcurrent
Step by step closed-loop DSP2 first path (X23) out of tolerance
Step by step closed-loop DSP1 second channel (X25) overcurrent
Step by step closed-loop DSP2 second channel (X21) out of tolerance
90V power overcurrent for stepper board
Main voltage (300V) too low
Main voltage (300V) too high
IPM overvoltage or overcurrent
Auxiliary equipment voltage (24V) too high
Auxiliary equipment voltage (24V) too low
Encoder malfunction or disconnection
Abnormal operation of the motor
Exceeding the sewing range during movement
Exceeding the sewing range during movement
Stepper driver communication exception
Stepper motor overcurrent
abnormal current
IPM frequent overcurrent 1
IPM frequent overcurrent 2
Motor stalling 1
Motor stalling 2
Motor overspeed
Parking overcurrent
Step by step overcurrent 1
Step by step overcurrent 2
Step out of tolerance 1
Pattern data error
Sewing range exceeds the left boundary
Sewing range exceeds the right boundary
Width exceeding the limit
Needle spacing exceeds the limit
Speed exceeds the limit
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Hardware overcurrent
Software overcurrent
Overvoltage during shutdown
Undervoltage during shutdown
Overvoltage during operation
Stop needle signal malfunction
Motor HALL signal fault
Motor stalling fault
Overspeed fault
Undervoltage during operation
HALLA signal loss
Motor overload
EEPROM error
Current detection circuit fault
Pedal zero position detection exceeds the limit
OZ circuit malfunction
Motor reversal
Motor angle test malfunction
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Loss of needle stop signal fault
Motor HALL signal initialization fault
Motor HALL_A signal loss fault
Initial angle fault of motor
Model code malfunction
motor stall
Motor stalling during wire cutting
Hardware driver failure
Overvoltage during shutdown
Overvoltage during operation
Undervoltage during shutdown
Undervoltage during operation
Current detection circuit fault
OZ circuit malfunction
Electromagnetic malfunction
Software overcurrent
Motor overspeed
Motor reversal
Communication data failure of operation box
Operation box malfunction
Pedal ID identification fault
Pedal zero position correction fault
Flip switch malfunction
Power off display
Hardware overcurrent
Software overcurrent
Overvoltage during shutdown
Undervoltage during shutdown
Overvoltage during operation
Stop needle signal malfunction
Motor HALL signal fault
Motor stalling fault
Overspeed fault
Undervoltage during operation
HALLA signal loss
Motor overload
EEPROM error
Current detection circuit fault
Pedal zero position detection exceeds the limit
OZ circuit malfunction
Motor reversal
Motor angle test malfunction
Input signal self-test error
power outage
Overvoltage
Electromagnetic overcurrent
locked-rotor
Communication failure on the operation panel
Abnormal positioning and needle stop
Exceeding the prescribed speed
Synchronizer self-test abnormal
EEPROM data abnormality
EEPROM parameter abnormality
Input signal self-test error
Abnormal signal feedback
power outage
Abnormal operation of the machine
Overcurrent and Overvoltage
Overvoltage
Electromagnetic overcurrent
locked-rotor
Abnormal positioning and needle stop
Exceeding the prescribed speed
Synchronizer self-test abnormal
EEPROM data abnormality
EEPROM parameter abnormality
Encoder abnormality
overvoltage
low voltage
CPU communication abnormality
Abnormal contact of speed controller
motor stall
Manual reverse sewing action time exceeds 15 seconds
Abnormal positioning signal
Electromagnetic overcurrent protection
Abnormal positioning signal
Encoder signal abnormality
Abnormal overcurrent protection for power module
The head protection switch is not in the correct position
Motor startup failure (electrical angle error)
Unable to find needle stop position
No speed regulator detected during startup
Motor Hall or phase line error
locked-rotor protection
Hardware overcurrent protection
Serial communication timeout error
The display screen is out of power
Unable to find needle stop position
Foot pedal signal error
Motor phase signal error
Motor stalling protection
Hardware overcurrent protection
Serial communication timeout
Poor memory
The foot pressure sensor has no signal
Reset sensor cannot find needle position
9700 error signal
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
No error reported
Pause switch position abnormal
Pause switch position abnormality 2
Poor contact of pause switch
Abnormal pedal position 1
Abnormal pedal position 2
Abnormal pedal position
Abnormal safety switch
Sewing machine position abnormality 1
Sewing machine position abnormality 2
Abnormal button position
Abnormal needle stop position
Abnormal upper stop needle position
Abnormal cutting position
Main motor abnormality
Encoder connection abnormality
Abnormal origin position of X
X motor is running abnormally
X Y origin abnormality
Y origin position is abnormal
Y motor running abnormally
Abnormal origin of presser foot
Abnormal operation of presser foot
No CF card
Data anomaly
CF card reading abnormality
Insufficient CF card capacity
CF card abnormality
Failed to read data
CF card without data program
Unable to read machine data
Beyond the sewing range 1
Beyond the sewing range 2
Needle spacing exceeds the maximum range
CF stores invalid data
No termination command input
Exceeding the maximum needle count range
data duplication
Prohibit changing programs
Overvoltage
Low voltage
Cooling fan not working
Contact Us